Off-center load cell for weighing systems, automatic dosage machines, medical, food, textile, and automation in general

Off-center load cell

Click on the image to enlarge

Off-center load cell CN2 Off-center load cell CN2 Drawing
ATEX IECEX

Technical specifications

MaterialStainless steel
Nominal load60, 120, 200, 250, 300 kg
Limit load150 % F.S.
Breaking load300 % F.S.
Supply voltageVcc 15 Max
Output2 mV/V
Output tollerance0,1 % F.S.
Zero tollerance1 % F.S.
Linearity0,03 % F.S.
Hysteresis0,03 % F.S.
Reapeatability0,03 % F.S.
Input resistance350 - 400 ohm
Output resistance350-353 ohm
Insulation resistance>= 2000 Mohm
Creep (30 Minutes)0,03 % F.S.
Thermal compensation-10 / +40°C (14 / +104°F)
Operating temperature-20 / +70°C (-4 / +158°F)
Temperature deviation zero0,003 % F.S. / °C
Temperature deviation full scale0,002 % F.S. / °C
Protection classIP 67
Standard cable length5 m – 6 x 0,30 (shield not connected to the load cell body)

For complete and up-to-date technical specifications please refer to the datasheet you can download here

Download PDF datasheet

Connections

TypeSHIELDED CABLE 6C R7 PUR 6X0,35
Length5 m (shield not connected to the cell body)
Red+ IN
Blue- IN
White+ REF
Black- REF
Yellow+ OUT
Green- OUT
Connections Off-center load cell CN2

Load cell mounting

General guidelines for installing and mounting load cells:

  • Respect the direction in which forces are applied to the load cells
  • Do not exceed the temperature limits shown on the rating plate
  • Do not remove the labels from the cells
  • Protect cables properly with sheaths or cable ducts
  • Connect each cell to earth with a suitable cable, bridging the plates of the mounting accessories if necessary
  • Do not weld on the mechanical structure once the cells are in place
  • Avoid or minimise mechanical constraints between the fixed structure and the weighed structure, to prevent weighing errors and zero return problems
  • When vibrations or dynamic loads are present, protect the cells with anti-vibration mounts
  • Protect the cells from dust build-up with suitable covers